Mfg Part Number: 25711-1 | Alternate P/N: 257111 |
Manufacturer: Microwave Engineering Corporation | NSN : 5985-01-342-3413 |
NIIN : 013423413 | Item Name : waveguide assembly |
CAGE Code : 06351 | FSC : 5985 Antennas Waveguides and Related Equipment |
Thank you for your interest in our available 25711-1 NSN part. This part number 25711-1 is a Waveguide Assembly listed under the FSC 5985 Antennas Waveguides and Related Equipment, and it is manufactured by Microwave Engineering Corporation. At Internet of Components, all of our stock and inventory are available for purchase today, ready to ship with short lead times and competitive pricing. Whether you are in need of parts that are new, used, or obsolete, our team of industry experts is readily available 24/7x365 to fulfill all of your operational
“*” Symbols for mandatory fields
Internet of Components is a premier supplier of 25711-1 NSN component, and we carry recently requested NSN components such as 5985013423413. We strive to only provide our customers with quality parts, which is why we choose to source our inventory from thousands of global manufacturers such as Microwave Engineering Corporation. If you are interested in this particular item, we invite you to begin the purchasing process for 25711-1 today by filling out and submitting an Instant RFQ. Once received, a member of our staff will review and reach out to you in 15 minutes or less to provide a personalized quote that caters towards your individual needs. Get started on the purchasing process today and see how we are revolutionizing the purchasing process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5985-01-342-3413 Item Description: Waveguide Assembly | 5985 | 013423413 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
25711-1 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL, RECTANGULAR DOUBLE RIDGED EXTERNAL, RECTANGULAR DOUBLE INDENTED |
AAJD | THREAD CLASS | 2B FIRST FLANGE SECOND CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND FIRST FLANGE SECOND CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS SINGLE TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSZ | FLANGE OUTSIDE WIDTH | 1.360 INCHES MINIMUM FIRST FLANGE AND 1.390 INCHES MAXIMUM FIRST FLANGE |
AHSZ | FLANGE OUTSIDE WIDTH | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.360 INCHES MINIMUM FIRST FLANGE AND 1.390 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM FIRST FLANGE AND 0.265 INCHES MAXIMUM FIRST FLANGE |
AHTD | FLANGE DEPTH | 0.423 INCHES MINIMUM SECOND FLANGE AND 0.453 INCHES MAXIMUM SECOND FLANGE |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.145 INCHES MINIMUM FIRST FLANGE FIRST CONNECTION FACILITY AND 0.148 INCHES MAXIMUM FIRST FLANGE FIRST CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.169 INCHES MINIMUM SECOND FLANGE ALL CONNECTION FACILITIES AND 0.172 INCHES MAXIMUM SECOND FLANGE ALL CONNECTION FACILITIES |
CMLP | THREAD QUANTITY PER INCH | 32 FIRST FLANGE SECOND CONNECTION FACILITY |
CQHN | WAVEGUIDE OUTSIDE WIDTH | 0.788 INCHES MINIMUM AND 0.794 INCHES MAXIMUM |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES FIRST FLANGE SECOND CONNECTION FACILITY |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.688 INCHES MINIMUM AND 0.694 INCHES MAXIMUM |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.318 INCHES MINIMUM AND 0.324 INCHES MAXIMUM |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 THREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE SECOND FLANGE ALL CONNECTION FACILITIES |
CTCJ | FLANGE STYLE | CONTACT, DOUBLE RIDGE TYPE FIRST FLANGE |
CTFD | WAVEGUIDE LENGTH | 3.365 INCHES MINIMUM AND 3.385 INCHES MAXIMUM |
MATT | MATERIAL | ALUMINUM ALLOY ALL TUBING SEGMENT AND FLANGE |
SFTT | SURFACE TREATMENT | CHROMATE ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES AND PAINT ALL TUBING SEGMENT AND FLANGE OUTSIDE SURFACES |
STYL | III STYLE DESIGNATOR | STRAIGHT TYPE |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |
FLEX | FLEXIBILITY | RIGID SINGLE TUBING SEGMENT |
AHSX | FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM FIRST FLANGE AND 0.694 INCHES MAXIMUM FIRST FLANGE |
AHSX | FLANGE INSIDE WIDTH | 1.003 INCHES MINIMUM SECOND FLANGE AND 1.006 INCHES MAXIMUM SECOND FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.318 INCHES MINIMUM FIRST FLANGE AND 0.324 INCHES MAXIMUM FIRST FLANGE |
AHSY | FLANGE INSIDE HEIGHT | 0.503 INCHES MINIMUM SECOND FLANGE AND 0.506 INCHES MAXIMUM SECOND FLANGE |
AHTA | FLANGE OUTSIDE HEIGHT | 1.610 INCHES MINIMUM SECOND FLANGE AND 1.640 INCHES MAXIMUM SECOND FLANGE |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.10 |
AHTX | INSERTION LOSS IN DECIBELS | 0.15 |
CSFC | WAVEGUIDE OUTSIDE HEIGHT | 0.418 INCHES MINIMUM AND 0.424 INCHES MAXIMUM |
CTCJ | FLANGE STYLE | COVER TYPE SECOND FLANGE |
THSD | THREAD SERIES DESIGNATOR | UNC FIRST FLANGE SECOND CONNECTION FACILITY |