Mfg Part Number: 4411 | Manufacturer: Electronic Precision Components Corp |
NSN : 5915-01-029-2039 | NIIN : 010292039 |
Item Name : filter band pass | CAGE Code : 33791 |
FSC : 5915 Filters and Networks |
Thank you for your interest in our available 4411 NSN part. This part number 4411 is a Filter Band Pass listed under the FSC 5915 Filters and Networks, and it is manufactured by Electronic Precision Components Corp. At Internet of Components, all of our stock and inventory are available for purchase today, ready to ship with short lead times and competitive pricing. Whether you are in need of parts that are new, used, or obsolete, our team of industry experts is readily available 24/7x365 to fulfill all of your operational
“*” Symbols for mandatory fields
Internet of Components is a premier supplier of 4411 NSN component, and we carry recently requested NSN components such as 5915010292039. We strive to only provide our customers with quality parts, which is why we choose to source our inventory from thousands of global manufacturers such as Electronic Precision Components Corp. If you are interested in this particular item, we invite you to begin the purchasing process for 4411 today by filling out and submitting an Instant RFQ. Once received, a member of our staff will review and reach out to you in 15 minutes or less to provide a personalized quote that caters towards your individual needs. Get started on the purchasing process today and see how we are revolutionizing the purchasing process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-01-029-2039 Item Description: Filter Band Pass | 5915 | 010292039 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
4411 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 0.993 INCHES NOMINAL |
ADAQ | BODY LENGTH | 6.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 1.750 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.868 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 5.000 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.250 INCHES NOMINAL |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 26.0 SINGLE RADIO INTERFERENCE PULSES PER SECOND |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 28.4 SINGLE RADIO INTERFERENCE TWO PHASE TO TWO PHASE |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 30.8 SINGLE RADIO INTERFERENCE TWO PHASE TO THREE PHASE |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 33.2 SINGLE RADIO INTERFERENCE HERTZ |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 35.6 SINGLE RADIO INTERFERENCE THREE PHASE TO TWO PHASE |
AHAJ | REFERENCE FREQUENCY PER FUNCTION | 38.0 SINGLE RADIO INTERFERENCE GIGAHERTZ |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 1ST BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 2ND BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 3RD BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 4TH BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 5TH BAND PASS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 1.0 OHMS 6TH BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH BAND PASS |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH BAND PASS |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 12 THREADED HOLE |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 1ST BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 2ND BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 3RD BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 4TH BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 5TH BAND PASS |
CQDR | INSERTION LOSS AT REFERENCE FREQUENCY PER FUNCTION IN DECIBELS | 3.0 6TH BAND PASS |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 PIN OUTPUT 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 6 PIN INPUT-OUTPUT/GROUND 3RD FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 22.80 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 25.90 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 26.10 KILOHERTZ 1ST BAND PASS 1ST FUNCTION AND 28.40 KILOHERTZ 1ST BAND PASS 1ST FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 26.40 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 28.30 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 28.50 KILOHERTZ 2ND BAND PASS 2ND FUNCTION AND 30.80 KILOHERTZ 2ND BAND PASS 2ND FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 28.40 KILOHERTZ 3RD BAND PASS 3RD FUNCTION AND 30.70 KILOHERTZ 3RD BAND PASS 3RD FUNCTION AND 30.90 KILOHERTZ 3RD BAND PASS 3RD FUNCTION AND 33.20 KILOHERTZ 3RD BAND PASS 3RD FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 30.80 KILOHERTZ 4TH BAND PASS 4TH FUNCTION AND 33.10 KILOHERTZ 4TH BAND PASS 4TH FUNCTION AND 33.30 KILOHERTZ 4TH BAND PASS 4TH FUNCTION AND 35.60 KILOHERTZ 4TH BAND PASS 4TH FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 33.20 KILOHERTZ 5TH BAND PASS 5TH FUNCTION AND 35.50 KILOHERTZ 5TH BAND PASS 5TH FUNCTION AND 35.70 KILOHERTZ 5TH BAND PASS 5TH FUNCTION AND 38.00 KILOHERTZ 5TH BAND PASS 5TH FUNCTION |
CQFC | SPECIFIED FREQUENCIES OF DISCRIMINATION PER FUNCTION | 35.60 KILOHERTZ 6TH BAND PASS 6TH FUNCTION AND 37.90 KILOHERTZ 6TH BAND PASS 6TH FUNCTION AND 38.10 KILOHERTZ 6TH BAND PASS 6TH FUNCTION AND 43.00 KILOHERTZ 6TH BAND PASS 6TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES |
CQRG | BODY MATERIAL | METAL |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 25.90 KILOHERTZ 1ST BAND PASS AND 26.10 KILOHERTZ 1ST BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 28.30 KILOHERTZ 2ND BAND PASS AND 28.50 KILOHERTZ 2ND BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 30.70 KILOHERTZ 3RD BAND PASS AND 30.90 KILOHERTZ 3RD BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 33.10 KILOHERTZ 4TH BAND PASS AND 33.30 KILOHERTZ 4TH BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 35.50 KILOHERTZ 5TH BAND PASS AND 35.70 KILOHERTZ 5TH BAND PASS |
CRBB | FREQUENCY BAND WIDTH PER FUNCTION | 37.90 KILOHERTZ 6TH BAND PASS AND 38.10 KILOHERTZ 6TH BAND PASS |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 1ST BAND PASS 1ST FUNCTION AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 3.0 MAXIMUM 1ST BAND PASS 1ST FUNCTION AND 30.0 MINIMUM 1ST BAND PASS 1ST FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 2ND BAND PASS 2ND FUNCTION AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 3.0 MAXIMUM 2ND BAND PASS 2ND FUNCTION AND 30.0 MINIMUM 2ND BAND PASS 2ND FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 3RD BAND PASS 3RD FUNCTION AND 3.0 MAXIMUM 3RD BAND PASS 3RD FUNCTION AND 3.0 MAXIMUM 3RD BAND PASS 3RD FUNCTION AND 30.0 MINIMUM 3RD BAND PASS 3RD FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 4TH BAND PASS 4TH FUNCTION AND 3.0 MAXIMUM 4TH BAND PASS 4TH FUNCTION AND 3.0 MAXIMUM 4TH BAND PASS 4TH FUNCTION AND 30.0 MINIMUM 4TH BAND PASS 4TH FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 5TH BAND PASS 5TH FUNCTION AND 3.0 MAXIMUM 5TH BAND PASS 5TH FUNCTION AND 3.0 MAXIMUM 5TH BAND PASS 5TH FUNCTION AND 30.0 MINIMUM 5TH BAND PASS 5TH FUNCTION |
CRBC | DISCRIMINATION AT SPECIFIED FREQUENCIES PER FUNCTION IN DECIBELS | 30.0 MINIMUM 6TH BAND PASS 6TH FUNCTION AND 3.0 MAXIMUM 6TH BAND PASS 6TH FUNCTION AND 3.0 MAXIMUM 6TH BAND PASS 6TH FUNCTION AND 30.0 MINIMUM 6TH BAND PASS 6TH FUNCTION |
CRST | BODY SURFACE TREATMENT | TIN |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.