Mfg Part Number: AM4-A3A3A3A6-A-50-2 | Alternate P/N: AM4A3A3A3A6A502 |
Manufacturer: Eaton Corp | NSN : 5925-01-287-4283 |
NIIN : 012874283 | Item Name : circuit breaker |
CAGE Code : 74193 | FSC : 5925 Circuit Breakers |
Thank you for your interest in our available AM4-A3A3A3A6-A-50-2 NSN part. This part number AM4-A3A3A3A6-A-50-2 is a Circuit Breaker listed under the FSC 5925 Circuit Breakers, and it is manufactured by Eaton Corp. At Internet of Components, all of our stock and inventory are available for purchase today, ready to ship with short lead times and competitive pricing. Whether you are in need of parts that are new, used, or obsolete, our team of industry experts is readily available 24/7x365 to fulfill all of your operational
“*” Symbols for mandatory fields
Internet of Components is a premier supplier of AM4-A3A3A3A6-A-50-2 NSN component, and we carry recently requested NSN components such as 5925012874283. We strive to only provide our customers with quality parts, which is why we choose to source our inventory from thousands of global manufacturers such as Eaton Corp. If you are interested in this particular item, we invite you to begin the purchasing process for AM4-A3A3A3A6-A-50-2 today by filling out and submitting an Instant RFQ. Once received, a member of our staff will review and reach out to you in 15 minutes or less to provide a personalized quote that caters towards your individual needs. Get started on the purchasing process today and see how we are revolutionizing the purchasing process.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-287-4283 Item Description: Circuit Breaker | 5925 | 012874283 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
AM4-A3A3A3A6-A-50-2 | 5 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-MULTIPLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 2.468 INCHES MINIMUM AND 2.532 INCHES MAXIMUM |
ADAT | BODY WIDTH | 2.968 INCHES MINIMUM AND 3.032 INCHES MAXIMUM |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 1.906 INCHES MINIMUM AND 1.970 INCHES MAXIMUM |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 0.722 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 2.030 INCHES MINIMUM AND 2.094 INCHES MAXIMUM |
AEGJ | SWITCH CONTACT ARRANGEMENT | SINGLE POLE, DOUBLE THROW |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 0.722 INCHES MINIMUM AND 0.782 INCHES MAXIMUM |
AJEC | BOSS HEIGHT | 0.140 INCHES MINIMUM AND 0.172 INCHES MAXIMUM |
AJWX | MOUNTING SURFACE TO TERMINAL END DISTANCE | 2.688 INCHES MINIMUM AND 2.752 INCHES MAXIMUM |
AKPX | POLE QUANTITY | 4 |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 8 THREADED HOLE |
CMLP | THREAD QUANTITY PER INCH | 32 |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC FIRST LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC SECOND LOCATION |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 50.0 AMPERES AC THIRD LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC FIRST LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC SECOND LOCATION |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC THIRD LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC FIRST LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC SECOND LOCATION |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 1000.0 AC THIRD LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT FIRST LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT SECOND LOCATION |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT THIRD LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC FIRST LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC SECOND LOCATION |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC THIRD LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY FIRST LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY SECOND LOCATION |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY THIRD LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 FIRST LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 SECOND LOCATION |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 THIRD LOCATION |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 4 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT EACH POLE |
CPRY | EXTERNAL ACTUATOR LINKAGE ARRANGEMENT | ONE, TWO, THREE, AND FOUR LINKED |
CPRZ | AUXILIARY SWITCH FUNCTION AND QUANTITY | 1 ALARM |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP FIRST LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP SECOND LOCATION |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP THIRD LOCATION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CQSM | SWITCH LOCATION AND POSITION DESIGNATION | EXTERNAL AT POLE FOUR |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT FIRST LOCATION AND 20.000 MAXIMUM AT 200 PCT FIRST LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT SECOND LOCATION AND 20.000 MAXIMUM AT 200 PCT SECOND LOCATION |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 2.000 MINIMUM AT 200 PCT THIRD LOCATION AND 20.000 MAXIMUM AT 200 PCT THIRD LOCATION |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND HUMIDITY RESISTANT AND MOISTURE RESISTANT AND SHOCK RESISTANT AND VIBRATION RESISTANT |
CRTK | SWITCH TERMINAL TYPE | THREADED STUD |
CSSX | SWITCH CURRENT RATING AND TYPE IN AMPS | 50.0 AC |
CSWP | SWITCH VOLTAGE RATING AND TYPE IN VOLTS | 250.0 AC |
FEAT | SPECIAL FEATURES | FOURTH POLE IS SWITCH ONLY |
FREQ | FREQUENCY IN HERTZ | 50.0 FOURTH LOCATION OR 60.0 FOURTH LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 FIRST LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 SECOND LOCATION |
FREQ | FREQUENCY IN HERTZ | 60.0 THIRD LOCATION |
PKWT | UNPACKAGED UNIT WEIGHT | 9.500 OUNCES |
THSD | THREAD SERIES DESIGNATOR | UNC |
TTQY | TERMINAL TYPE AND QUANTITY | 8 THREADED STUD |
Don’t forget That If You’d Ever Like a Quote for Parts Within 15 Minutes or Less, You Can Fill out the Instant RFQ form On this Website’S Homepage.